If you have ever looked down a certified laboratory water test or scanned the fine print on a municipal water quality report, you have probably run into a wall of chemical names that look like they were built to keep regular homeowners out of the conversation. Two of the most common tongue-twisters on that list are cis-1,2-dichloroethylene and trans-1,2-dichloroethylene.
When a homeowner hands me a lab report with one of these names highlighted, the first reaction is usually confusion, followed closely by worry. That is completely understandable. You should not need a chemistry degree to understand what is coming out of your kitchen tap, and you should never be left guessing whether a number on a page is a real problem or just background noise. My job has always been to strip away the jargon, look at the actual facts, and explain how water treatment handles the problem in the real world.
Let us break down what these two chemicals actually are, where they come from, what the federal numbers mean, and how we get them out of drinking water.
1. What They Are
At the most basic level, cis-1,2-dichloroethylene and trans-1,2-dichloroethylene are two forms of the exact same industrial solvent chemical: 1,2-dichloroethylene. In chemistry, two forms of the same compound are called isomers.
Here is the simplest way to picture what an isomer is without getting bogged down in textbook diagrams. Both of these chemicals are built out of the exact same atoms in the exact same amounts. The only difference between them is how those atoms are arranged in space around the center of the molecule. In the cis form, specific atoms sit on the same side of the molecule. In the trans form, those same atoms sit on opposite sides of the molecule.
That might sound like a tiny, academic detail, and in many ways it is. You cannot see, taste, or smell the difference in a glass of water. However, changing the geometry of a molecule changes its physical and chemical properties slightly. Because the cis version and the trans version behave a little differently in the environment and inside the human body, federal regulators do not lump them together under one single rule. They track them separately and give each one its own set of regulations.
Both forms belong to a broader family of chemicals known as volatile organic compounds, or VOCs. In plain English, “volatile” does not mean explosive; it means the chemical evaporates easily. If you leave a glass of water containing a VOC sitting out on the counter, the chemical wants to escape the water and drift into the air. That single trait—the tendency to evaporate out of water readily—is the key to understanding both how these chemicals move through the environment and how we remove them from a water supply.
2. Where They Come From
Neither cis-1,2-dichloroethylene nor trans-1,2-dichloroethylene occurs naturally in rocks, soil, or rainwater. They are strictly man-made industrial chemicals. If you ask the U.S. Environmental Protection Agency where they come from, the official federal source line for both is direct and simple: “Discharge from industrial chemical factories.”
That covers direct releases from facilities that manufacture or use solvents. However, in my experience looking at real-world groundwater tests, there is a second story that explains why these chemicals show up in wells and water systems years after a factory has closed its doors.
Both forms also appear in groundwater as breakdown products when stronger, heavier industrial solvents degrade underground. Specifically, when trichloroethylene (TCE) and tetrachloroethylene (PCE) sit in soil and groundwater over time, natural underground processes slowly break them down piece by piece. As TCE and PCE lose atoms and degrade, they transform into 1,2-dichloroethylene.
This is why cis- and trans-1,2-dichloroethylene so frequently turn up at old degreasing operations, former manufacturing plants, and legacy industrial sites. Even if a facility never poured 1,2-dichloroethylene directly onto the ground, heavy use of TCE or PCE decades ago can leave behind a trail of breakdown products moving slowly through the aquifer. And when that underground breakdown happens, nature favors one shape over the other: of the two isomers, the cis form is the one usually found in water. Seeing the cis form on a lab report is often a classic clue that older industrial solvents have been breaking down somewhere upgradient in the groundwater.
3. The Numbers
When you look at a water test, a chemical name means nothing without the numbers next to it. To read those numbers properly, you have to understand the two yardsticks the EPA uses to regulate drinking water contaminants: the MCLG and the MCL.
An MCLG is a Maximum Contaminant Level Goal. This is a non-enforceable health goal. It represents the level of a contaminant in drinking water below which there is no known or expected risk to health. It is set strictly based on health science, without factoring in treatment costs or technology limits.
An MCL is a Maximum Contaminant Level. This is the enforceable legal limit. Public water systems are required by law to keep their water at or below this number, using the best available treatment technology while taking cost into account.
For cis-1,2-dichloroethylene and trans-1,2-dichloroethylene, the federal limits are straightforward, and notably, for both of these chemicals, the health goal and the enforceable legal limit are the exact same number:
- Cis-1,2-dichloroethylene:
- Health goal (MCLG): 0.07 mg/L (70 ppb)
- Legal limit (MCL): 0.07 mg/L (70 ppb)
- Trans-1,2-dichloroethylene:
- Health goal (MCLG): 0.1 mg/L (100 ppb)
- Legal limit (MCL): 0.1 mg/L (100 ppb)
Notice how the cis form has a tighter limit than the trans form—70 parts per billion compared to 100 parts per billion. That goes right back to what we talked about earlier: because the atoms sit on the same side of the molecule in the cis form, its properties differ slightly from the trans form, earning it a stricter federal standard. Also notice that whether your report lists the result in milligrams per liter (mg/L) or parts per billion (ppb), those two figures represent the exact same concentration—just written in different units on the lab sheet.
4. What EPA Says About Health
Whenever a synthetic chemical shows up in a water report, the internet is full of people ready to scare homeowners with worst-case scenarios and laundry lists of scary medical terms. I do not play that game, and neither does the federal government. We stick strictly to what the regulators have established.
In the EPA’s official drinking water standards, the health language for both cis-1,2-dichloroethylene and trans-1,2-dichloroethylene comes down to two exact words: “Liver problems.”
That is the entire federal health statement for both isomers. In plain terms, what this means is that when regulators evaluate the risk of ongoing exposure to these solvents in drinking water above the legal limits, the primary organ of concern is the liver. Your liver is your body’s main chemical processing and filtering plant; it is the organ tasked with breaking down and clearing foreign substances that enter your bloodstream. When water carries industrial solvents like 1,2-dichloroethylene at elevated levels over time, the liver takes the brunt of that workload.
You do not need to speculate beyond what the EPA actually states. Keeping concentrations below the legal limits is designed specifically to protect against those liver problems.
5. What Removes Them
If a water test confirms that cis- or trans-1,2-dichloroethylene is present, the good news is that these are well-understood chemicals with proven, straightforward removal methods. We do not have to guess at what works. Under the EPA’s federal treatment table, the designated Best Available Technology for both forms is packed tower aeration and granular activated carbon.
Let us translate both of those engineering terms into plain English so you know what is actually happening inside the equipment.
Packed tower aeration takes direct advantage of the fact that these chemicals are volatile organic compounds. Since 1,2-dichloroethylene naturally wants to evaporate out of water into the air, packed tower aeration forces that process to happen quickly under controlled conditions. Water is trickled down through a tall tower filled with specially shaped packing material that breaks the water into thin films and tiny droplets, maximizing its surface area. At the same time, clean air is blown upward through the tower. As the air and water mix, the volatile solvent molecules strip out of the water and vent safely into the air, leaving clean water to collect at the bottom. You will mostly see packed tower aeration used at municipal water treatment plants or large community well systems where high volumes of water need to be treated continuously.
Granular activated carbon (GAC) works on a completely different principle called adsorption—with a “d,” not a “b.” Instead of soaking up water like a sponge absorbs liquid, activated carbon acts like a massive molecular magnet. Carbon is processed to create millions of microscopic pores and tunnels, giving a small amount of carbon an enormous internal surface area. As water flows through a bed of granular activated carbon, organic solvent molecules like cis- and trans-1,2-dichloroethylene stick to the surfaces of those carbon pores and stay trapped there, while clean water passes right on through.
For a homeowner dealing with a private well or looking to protect their house, here is the practical translation: you are not going to put a municipal packed aeration tower in your basement. While aeration is a workhorse at the treatment-plant level, granular activated carbon is the working answer at the residential point-of-entry level. When installed where the main water line enters the home, a properly sized carbon system treats all the water coming into the house—which matters with VOCs because you do not just drink your water; you also shower in it, wash dishes in it, and breathe the air inside your home where volatile chemicals could otherwise evaporate.
One important note on equipment shopping: do not get distracted by micron ratings when looking at VOC removal. A micron rating tells you the physical size of solid particles—like sand, silt, or rust—that a sediment cartridge can block. Cis- and trans-1,2-dichloroethylene are dissolved volatile chemicals, not solid specks of dirt floating in the pipe. Trying to catch a dissolved solvent with a sediment filter is like trying to catch wind in a chain-link fence. Skip the micron ratings entirely for this job; the honest, proven tools are air and carbon.
6. The Bottom Line
Cis- and trans-1,2-dichloroethylene are two regulated leftovers of the industrial solvent age—and when a water test finds them, it is often the underground fingerprint of older, stronger solvents breaking down nearby, which is always worth knowing about your water.
Facts first, then filter. — Steve